Power rating
|
15 W
|
Item
|
Output voltage
|
5 V
|
12 V
|
15 V
|
24 V
|
Efficiency
|
100 VAC input
|
80% typ.
|
84% typ.
|
84% typ.
|
85% typ.
|
200 VAC input
|
80% typ.
|
84% typ.
|
84% typ.
|
86% typ.
|
230 VAC input
|
80% typ.
|
84% typ.
|
84% typ.
|
86% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50/60 Hz (47 to 450 Hz)
|
Current
|
100 VAC input
|
0.32 A typ.
|
200 VAC input
|
0.2 A typ.
|
Power factor
|
−
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
3 A
|
1.3 A
|
1 A
|
0.65 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
40 mVp-p max.
|
40 mVp-p max.
|
40 mVp-p max.
|
60 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
15 ms typ.
|
14 ms typ.
|
15 ms typ.
|
15 ms typ.
|
200 VAC input
|
75 ms typ.
|
70 ms typ.
|
75 ms typ.
|
70 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
No
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with connector option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option)
CSA C22.2 No.60950-1 (excluding models with connector option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
30 W
|
Item
|
Output voltage
|
5 V
|
12 V
|
15 V
|
24 V
|
Efficiency
|
100 VAC input
|
81% typ.
|
84% typ.
|
86% typ.
|
86% typ.
|
200 VAC input
|
81% typ.
|
86% typ.
|
88% typ.
|
88% typ.
|
230 VAC input
|
81% typ.
|
86% typ.
|
88% typ.
|
89% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50/60 Hz (47 to 450 Hz)
|
Current
|
100 VAC input
|
0.72 A typ.
|
200 VAC input
|
0.43 A typ.
|
Power factor
|
−
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
6 A
|
3 A
|
2.4 A
|
1.5 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
50 mVp-p max.
|
60 mVp-p max.
|
50 mVp-p max.
|
60 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
11 ms typ.
|
10 ms typ.
|
11 ms typ.
|
10 ms typ.
|
200 VAC input
|
60 ms typ.
|
50 ms typ.
|
50 ms typ.
|
55 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
No
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with connector option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option)
CSA C22.2 No.60950-1 (excluding models with connector option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
50 W
|
Item
|
Output voltage
|
5 V
|
12 V
|
15 V
|
24 V
|
Efficiency
|
100 VAC input
|
81% typ.
|
84% typ.
|
86% typ.
|
86% typ.
|
200 VAC input
|
82% typ.
|
86% typ.
|
88% typ.
|
89% typ.
|
230 VAC input
|
82% typ.
|
86% typ.
|
88% typ.
|
89% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50/60 Hz (47 to 450 Hz)
|
Current
|
100 VAC input
|
1.1 A typ.
|
200 VAC input
|
0.62 A typ.
|
Power factor
|
−
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
8 A
|
4.3 A
|
3.5 A
|
2.2A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
|
|
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
40 mVp-p max.
|
40 mVp-p max.
|
40 mVp-p max.
|
60 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
14 ms typ.
|
11 ms typ.
|
10 ms typ.
|
10 ms typ.
|
200 VAC input
|
75 ms typ.
|
60 ms typ.
|
60 ms typ.
|
55 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
No
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with connector option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option)
CSA C22.2 No.60950-1 (excluding models with connector option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
100 W
|
Item
|
Output voltage
|
5 V
|
12 V
|
15 V
|
24 V
|
Efficiency
|
100 VAC input
|
79% typ.
|
84% typ.
|
85% typ.
|
87% typ.
|
200 VAC input
|
81% typ.
|
86% typ.
|
87% typ.
|
89% typ.
|
230 VAC input
|
81% typ.
|
86% typ.
|
87% typ.
|
89% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50/60 Hz (47 to 450 Hz)
|
Current
|
100 VAC input
|
2.1 A typ.
|
200 VAC input
|
1.2 A typ.
|
Power factor
|
−
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
16 A
|
8.5 A
|
7 A
|
4.5 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
70 mVp-p max.
|
90 mVp-p max.
|
100 mVp-p max.
|
80 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
12 ms typ. 11 ms typ. 11 ms typ. 10 ms typ.
|
200 VAC input
|
70 ms typ.
|
55 ms typ.
|
55 ms typ.
|
55 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
Yes (Only for models with remote control option)
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Only Remote control
500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with connector option or remote control option)
UL 508 (Recognition, models with remote control option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option or remote control option)
CSA C22.2 No.60950-1 (excluding models with connector option or remote control option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
150 W
|
Item
|
Output voltage
|
5 V
|
12 V
|
15 V
|
24 V
|
48 V
|
Efficiency
|
100 VAC input
|
78% typ.
|
84% typ.
|
85% typ.
|
87% typ.
|
85% typ.
|
200 VAC input
|
81% typ.
|
87% typ.
|
88% typ.
|
89% typ.
|
88% typ.
|
230 VAC input
|
81% typ.
|
87% typ.
|
88% typ.
|
90% typ.
|
88% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50 /60 Hz (47 to 450 Hz)
|
Current
|
100 VAC input
|
3 A typ.
|
200 VAC input
|
1.8 A typ.
|
Power factor
|
−
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
21 A
|
13 A
|
10 A
|
6.5 A
|
3.3 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
100 mVp-p max.
|
110 mVp-p max.
|
80 mVp-p max.
|
110 mVp-p max.
|
120 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
14 ms typ.
|
10 ms typ.
|
10 ms typ.
|
10 ms typ.
|
11 ms typ.
|
200 VAC input
|
80 ms typ.
|
55 ms typ.
|
55 ms typ.
|
55 ms typ.
|
55 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
Yes (Only for models with remote control option)
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min.(between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min.(between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min.(between all output terminals and PE terminals) current cutoff 20 mA
|
Only Remote control
500 VAC for 1 min.(between all output terminals and RC terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min.(between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2 (Applicable at 80% or less of the rated load.)
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with connector option or remote control option)
UL 508 (Recognition, models with remote control option) UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option or remote control option)
CSA C22.2 No.60950-1 (excluding models with connector option or remote control option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
300 W
|
Item
|
Output voltage
|
12 V
|
15 V
|
24 V
|
48 V
|
Efficiency
|
100 VAC input
|
81% typ.
|
81% typ.
|
82% typ.
|
82% typ.
|
200 VAC input
|
85% typ.
|
85% typ.
|
87% typ.
|
87% typ.
|
230 VAC input
|
85% typ.
|
86% typ.
|
87% typ.
|
87% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 370 VDC
|
Frequency
|
50/60 Hz (47 to 63 Hz)
|
Current
|
100 VAC input
|
4.2 A typ.
|
200 VAC input
|
2.1 A typ.
|
Power factor
|
0.9 min.
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
25 A
|
20 A
|
14 A
|
7 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
140 mVp-p max.
|
270 mVp-p max.
|
150 mVp-p max.
|
330 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
30 ms typ.
|
30 ms typ.
|
30 ms typ.
|
30 ms typ.
|
200 VAC input
|
30 ms typ.
|
25 ms typ.
|
30 ms typ.
|
30 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
Yes, power shut off (shut off the input voltage and turn on the input again)
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
Yes (Only for models with remote control option)
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Only Remote control 500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with remote control option)
UL 508 (Recognition, models with remote control option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with remote control option)
CSA C22.2 No.60950-1 (excluding models with remote control option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|
Power rating
|
600 W
|
Item
|
Output voltage
|
12 V
|
15 V
|
24 V
|
48 V
|
Efficiency
|
100 VAC input
|
84% typ.
|
84% typ.
|
85% typ.
|
88% typ.
|
200 VAC input
|
88% typ.
|
88% typ.
|
89% typ.
|
92% typ.
|
230 VAC input
|
88% typ.
|
88% typ.
|
90% typ.
|
92% typ.
|
Input
|
Voltage range
|
Single phase, 85 to 264 VAC, 120 to 350 VDC
|
Frequency
|
50/60 Hz (47 to 63 Hz)
|
Current
|
100 VAC input
|
7.7 A typ.
|
200 VAC input
|
3.8 A typ.
|
Power factor
|
0.9 min.
|
Leakage current
|
100 VAC input
|
0.5 mA max.
|
200 VAC input
|
1 mA max.
|
Inrush current
(for a cold start at 25°C)
|
100 VAC input
|
14 A typ.
|
200 VAC input
|
28 A typ.
|
Output
|
Rated Output Current
|
50 A
|
40 A
|
27 A
|
13 A
|
Voltage adjustment range
|
−10% to 15% (with V.ADJ)
|
Ripple & Noise voltage
|
100 to 240 VAC input
|
170 mVp-p max.
|
170 mVp-p max.
|
280 mVp-p max.
|
340 mVp-p max.
|
Input variation influence
|
0.5% max.
|
Load variation influence
|
1.0% max.
|
Temperature variation influence
|
100 to 240 VAC input
|
0.05%/°C max.
|
Startup time
|
100 VAC input
|
1,000 ms max.
|
200 VAC input
|
1,000 ms max.
|
Hold time
|
100 VAC input
|
30 ms typ.
|
25 ms typ.
|
30 ms typ.
|
30 ms typ.
|
200 VAC input
|
30 ms typ.
|
25 ms typ.
|
30 ms typ.
|
30 ms typ.
|
Additional functions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection
|
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
Yes, power shut off (shut off the input voltage and turn on the input again)
|
Series operation
|
Yes (For up to two Power Supplies, external diodes are required.)
|
Parallel operation
|
Yes (up to five Power Supplies, S8FS-G60024 (models with parallel operation option) only).
|
Remote sensing
|
No
|
Remote control
|
Yes (Only Remote control)
|
Output indicator
|
Yes (LED: Green)
|
Insulation
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Only Remote control
500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Environment
|
Ambient operating temperature
|
−20 to 70°C (with no condensation or icing)
|
Storage temperature
|
−25 to 75°C (with no condensation or icing)
|
Ambient operating humidity
|
90% max. (Storage humidity: 90% max.)
|
Vibration resistance
|
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s², 3 times each in ±X, ±Y, ±Z directions
|
Reliability
|
MTBF
|
135,000 hrs min.
|
Life expectancy
|
10 years min.
|
Standards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
UL 508 (Listing, excluding models with remote control option)
UL 508 (Recognition, models with remote control option)
UL 60950-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with remote control option)
CSA C22.2 No.60950-1 (excluding models with remote control option)
EN 50178 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN 60950-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16.
|
Marine Standards
|
No
|
SEMI
|
Conforms to F47-0706 (200 VAC input)
|