
NJ3
Controller Sysmac – Serie NJ3
La serie NJ3 espande la soluzione dei controller Sysmac a 4 e 8 assi.
- Tempo di ciclo più veloce: 500 µs
- Numero di assi: 8, 4
- Motion core sincronizzato
- Funzioni: sequenziamento logico e movimento
- Multitasking
- Porte EtherCAT ed EtherNet/IP integrate
- La topologia ad anello EtherCAT è supportata per mantenere le comunicazioni e il controllo in caso di rottura di cavi o guasti del dispositivo
Caratteristiche ed info per ordinare
Ordering information
NJ series system

NJ series expansion racks

Power supply units
Note: Power supply units for the CJ Series cannot be used as a power supply for a CPU rack of the NJ System or as a power supply for an expansion rack.
NJ3 series CPU units
Note: The end cover unit CJ1W-TER01 is included with the CPU unit.
CJ series digital I/O units
Note: MIL = Connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
CJ series analog I/O and control units
Accuracy1 |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal inputs, with zero/span adjustment, configurable alarms, scaling, sensor error detection |
||||||||||||
Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold |
||||||||||||
All inputs individually isolated, configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment |
||||||||||||
Configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment, square root, totaliser |
||||||||||||
Basic I/O unit, setup by DIP switches, adjustable filtering |
||||||||||||
Basic I/O unit, setup by DIP switches, adjustable filtering |
||||||||||||
CJ series special I/O units
CJ series communication units
CJ1W-EIP212 |
|||||||||
CJ1W-ECT213 |
|||||||||
CJ1W-CRM214 |
|||||||||
RS-232C to RS-422A/RS-485 signal converter. Mounts directly on serial port |
CJ series ID sensor units
0.265 |
0.131 |
|||||||
Note: The data transfer function using intelligent I/O commands can not be used.
Expansion racks
CJ series I/O control unit (mounted on CPU rack when connecting expansion racks)
Note: Mount to the right of the power supply unit.
I/O connecting cables
EtherCAT junction slave
- Note 1. Please do not connect EtherCAT junction slave with OMRON position control unit, Model CJ1W-NC_81/_82.
- 2. EtherCAT junction slave cannot be used for Ethernet/IP and Ethernet.
Industrial switching hubs
![]() |
Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation |
||||||
Recommended EtherCAT and EtherNet/IP communication cables
Cable with connectors on both ends ![]() |
|||||||
Cable with connectors on both ends ![]() |
|||||||
Cable with connectors on both ends (RJ45/RJ45) ![]() |
|||||||
Cable sheath material: PUR1 |
Cable with connectors on both ends (RJ45/RJ45) ![]() |
||||||
Cable with connectors on both ends (RJ45/RJ45) ![]() |
|||||||
Cable with connectors on both ends (M12 straight/RJ45) ![]() |
|||||||
Cable with connectors on both ends (M12 L right angle/RJ45) ![]() |
|||||||
Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) |
|||||||
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) |
|||||||
DIN-rail mount socket to terminate installation cable in the cabinet |
Note: Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
WE70 FA wireless LAN units
![]() |
||||
Note: Special versions are available for USA, Canada, China and Japan.
NJ series options and accessories
Computer software
SYSMAC-SE2___8 |
1.
Accuracy for voltage and current inputs/outputs as percentage of full scale and typical value at 25°C ambient temperature (consult the operation manual for details)
Accuracy for temperature inputs/outputs as percentage of process value and typical value at 25°C ambient temperature (consult the operation manual for details)
2. Supported only by the EtherNet/IP units with unit version 2.1 or later, CPU units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher.
3. Supported only by the CPU units with unit version 1.10 or higher and the Sysmac Studio version 1.13 or higher.
4. Supported only by the CPU units with unit version 1.01 or higher and the Sysmac Studio version 1.02 or higher.
1.
Accuracy for voltage and current inputs/outputs as percentage of full scale and typical value at 25°C ambient temperature (consult the operation manual for details)
Accuracy for temperature inputs/outputs as percentage of process value and typical value at 25°C ambient temperature (consult the operation manual for details)
2. Supported only by the EtherNet/IP units with unit version 2.1 or later, CPU units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher.
3. Supported only by the CPU units with unit version 1.10 or higher and the Sysmac Studio version 1.13 or higher.
4. Supported only by the CPU units with unit version 1.01 or higher and the Sysmac Studio version 1.02 or higher.
Come possiamo aiutarti?
Se hai domande o desideri richiedere un preventivo, contattaci o inviaci una richiesta.
Contattaci NJ3

Grazie per averci sottoposto la vostra richiesta. Vi risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadPreventivo per NJ3
Tramite questo modulo può richiedere un'offerta relativa al prodotto prescelto. Completi, per favore, i campi contrassegnati con *. I suoi dati personali verranno trattati secondo le normative vigenti. Le ricordo che il minimo importo fatturabile è di 400 € a cui bisogna aggiungere 25 € di spese amministrative.

Grazie per averci richiesto un'offerta. Vi risponderemo non appena possibile.
Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.
DownloadEtherCAT Redundancy

La ridondanza riduce al minimo i tempi di inattività
Anche se una parte della rete EtherCAT è scollegata, la ridondanza dei cavi offre una connettività continua.
Questa funzione consente di effettuare la riparazione senza arrestare le macchine e la linea di produzione con un unico dispositivo in grado di controllare macchine e sicurezza.
Prodotti
-
Sicurezza integrata nell'automazione delle macchine
-
Da 8 a 64 punti per modulo di ingresso, di uscita o misto
-
Aperti a qualsiasi comunicazione
-
Dall'I/O analogico di base alla termoregolazione avanzata
-
Soluzioni di controllo del movimento per PLC serie CJ
-
Serie NA: HMI Sysmac
-
Prestazioni e praticità per il controllo delle macchine
-
Servoazionamento per impieghi generali Sysmac
-
Maggiore produttività e ambiente più sicuro
-
Migliora la produttività
Area di download

NJ-series -[DeviceNet]- ABB IRC5 Robot Controller Guida alla connessione
Effettua il login oppure registrati ai contenuti di questa pagina

NJ-series -[DeviceNet]- ABB IRC5 Robot Controller Guida alla connessione
Effettua il login oppure registrati ai contenuti di questa pagina

NJ-series -[EtherCAT]- Balluff BNI ECT-508 Guida alla connessione
Effettua il login oppure registrati ai contenuti di questa pagina
_cg_en.jpg)
NJ-series -[EtherCAT]- Balluff RFID (BIS V Series) Guida alla connessione
Effettua il login oppure registrati ai contenuti di questa pagina