ZX1

Caratteristiche

Il massimo delle prestazioni per una produttività ottimizzata

Le più alte prestazioni ora sono disponibili in dimensioni minime. Stiamo definendo una nuova classe di sensori di misurazione che utilizzano un chip telecamera HSDR-CMOS (High Speed and Dynamic Range, ad alta velocità e a gamma dinamica).

  • Misura stabile di oggetti con qualsiasi tipo di superficie
  • Prestazioni all'avanguardia in termini di precisione e velocità
  • Dimensioni compatte per un montaggio rapido
  • Gamma di misure ampliata
  • Configurazione semplice tramite un solo pulsante, tuning intelligente
  • Misure affidabili anche negli ambienti più difficili
  • Display integrato
Caratteristiche ed info per ordinare

Ordering information

Sensors

Appearance

Connection method

Cable length

Sensing distance

Order code

NPN output

PNP output

 

Pre-wired

2 m

 

ZX1-LD50A61 2M

ZX1-LD50A81 2M

5 m

ZX1-LD50A61 5M

ZX1-LD50A81 5M

Pre-wired connector

0.5 m

ZX1-LD50A66 0.5M

ZX1-LD50A86 0.5M

Pre-wired

2 m

 

ZX1-LD100A61 2M

ZX1-LD100A81 2M

5 m

ZX1-LD100A61 5M

ZX1-LD100A81 5M

Pre-wired connector

0.5 m

ZX1-LD100A66 0.5M

ZX1-LD100A86 0.5M

 

Pre-wired

2 m

 

ZX1-LD300A61 2M

ZX1-LD300A81 2M

5 m

ZX1-LD300A61 5M

ZX1-LD300A81 5M

Pre-wired connector

0.5 m

ZX1-LD300A66 0.5M

ZX1-LD300A86 0.5M

Pre-wired

2 m

 

ZX1-LD600A61 2M

ZX1-LD600A81 2M

5 m

ZX1-LD600A61 5M

ZX1-LD600A81 5M

Pre-wired connector

0.5 m

ZX1-LD600A66 0.5M

ZX1-LD600A86 0.5M

Accessories (sold separately)

 

Extension cables for pre-wired connector models

An Extension cable is not provided with the sensor. Order an extension cable separately.

 

Cable length

Order code

10 m

ZX0-XC10R

20 m

ZX0-XC20R

Specifications

 

Model

NPN output

ZX1-LD50A61

ZX1-LD50A66

ZX1-LD100A61

ZX1-LD100A66

ZX1-LD300A61

ZX1-LD300A66

ZX1-LD600A61

ZX1-LD600A66

 

Item

PNP output

ZX1-LD50A81

ZX1-LD50A86

ZX1-LD100A81

ZX1-LD100A86

ZX1-LD300A81

ZX1-LD300A86

ZX1-LD600A81

ZX1-LD600A86

Measurement range

50±10 mm

100±35 mm

300±150 mm

600±400 mm

Light source (wave length)

Visible-light semiconductor laser
(wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class II 1 )

Spot diameter (typical)

(Defined at the measurement center distance) 2

0.17 mm dia.

0.33 mm dia.

0.52 mm dia.

0.56 mm dia.

Power supply voltage

10 to 30 VDC, including 10% ripple (p-p)

Current consumption

250 mA max. (at power supply voltage 10 VDC)

Control output

Load power supply voltage: 30 VDC max., Load current: 100 mA max.

(Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA))

Analog output

Current output: 4 to 20 mA, maximum load resistance: 300 Ω

Indicators

Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator (orange), menu indicator (orange), laser ON indicator (green), and smart tuning indicator (blue)

Response time

Judgment output

Super-high-speed (SHS) Mode: 1 ms

High-speed (HS) Mode: 10 ms

Standard (Stnd) Mode: 100 ms

Laser OFF input

200 ms max.

Zero reset input

200 ms max.

Temperature characteristic 3

0.03% F.S./°C

0.04% F.S./°C

Linearity 4

±0.15% F.S.

±0.25% F.S.

±0.25% F.S.

(200 to 600 mm)

±0.5% F.S.

(entire range)

Resolution 5

2 µm

7 µm

30 µm

80 µm

Ambient illumination

Illumination on received light surface:

7,500 lx or less (incandescent light)

Illumination on received light surface:

5,000 lx or less (incandescent light)

Ambient temperature

Operating: -10 to 55°C, Storage: -15 to 70°C (with no icing or condensation)

Ambient humidity

Operating and storage: 35% to 85% (with no condensation)

Dielectric strength

1,000 VAC, 50/60 Hz, 1 minute3

Vibration resistance (destruction)

10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions

Shock resistance (destruction)

500 m/s2 3 times each in X, Y, and Z directions

Degree of protection 6

IEC 60529, IP67

Connection method

Pre-wired model (Standard cable length: 2 m, 5 m)

Pre-wired connector model (Standard cable length: 0.5 m)

Weight

(packed state/

sensor only)

Pre-wired models (2 m)

Approx. 240 g / Approx. 180 g

Approx. 270 g / Approx. 210 g

Pre-wired models (5 m)

Approx. 450 g / Approx. 330 g

Approx. 480 g / Approx. 360 g

Pre-wired connector models (0.5 m)

Approx. 170 g / Approx. 110 g

Approx. 200 g / Approx. 140 g

Materials

Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable: PVC, Mounting hole part: SUS303

Accessories

Instruction sheet and Laser warning label (English)

Note: False detection outside the measurement range can occur in the case of an object with high reflectance.

 


1. Classified as Class 2 by EN60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. Notification to CDRH planned. (Center for Devices and Radiological Health)

2. Spot diameter: Defined as 1/e² (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.

3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)

4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25°C. Linearity and measured value may vary depending on target object.

5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.

6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected.

1. Classified as Class 2 by EN60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. Notification to CDRH planned. (Center for Devices and Radiological Health)

2. Spot diameter: Defined as 1/e² (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.

3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)

4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25°C. Linearity and measured value may vary depending on target object.

5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.

6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected.

Avete delle domande?

Siamo a vostra intera disposizione.

Contattateci

Iscrivetevi agli aggiornamenti di prodotti

Newsletter sulle ultime novità e innovazioni in termini di prodotti, soluzioni e servizi direttamente nella vostra casella di posta.

Grazie per la tua iscrizione! Riceverai a breve una E-mail di conferma con un link per attivare il servizio. Questo sistema di iscrizione è stato scelto per ottemperare alla legge sulla privacy e garantisce la riservatezza del tuo indirizzo E-mail.

Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.

Download

Documentazione di prodotto

Scarica le schede tecniche, i manuali e le brochure.

Vai al Download Center

Corsi di formazione

Accedete ai corsi di formazione offerti dai nostri tecnici qualificati. Dal livello principiante ad avanzato.

Visualizzate i corsi di formazione