G9SA

Caratteristiche

Unità di sicurezza a relè espandibile

La famiglia G9SA offre una gamma completa di unità di sicurezza a relè compatte ed espandibili. Sono disponibili moduli temporizzati con ritardo alla diseccitazione e una unità di controllo a due mani. Semplice espansione dei contatti di sicurezza tramite la connessione frontale.
  • Custodia con larghezza 45 mm; moduli di espansione con larghezza 17,5 mm
  • Moduli temporizzati con ritardo alla diseccitazione
  • Semplicità di collegamento dei moduli di espansione
  • Certificazione fino a PLe secondo EN ISO 13849-1 a seconda dell'applicazione
Caratteristiche ed info per ordinare

Ordering information

Emergency-stop units

Main contacts

Auxiliary contact

Number of input channels

Rated voltage

Order code

3PST-NO

SPST-NC

1 channel or 2 channels possible

24 VAC/VDC

G9SA-301

100 to 240 VAC

5PST-NO

SPST-NC

1 channel or 2 channels possible

24 VAC/VDC

G9SA-501

100 to 240 VAC

Emergency-stop OFF-delay units

Main contacts

OFF-delay contacts

Auxiliary

contact

Number of

input channels

OFF-delay time

Rated voltage

Order code

3PST-NO

DPST-NO

SPST-NC

1 channel or
2 channels
possible

7.5 s

24 VAC/VDC

G9SA-321-T075

100 to 240 VAC

15 s

24 VAC/VDC

G9SA-321-T15

100 to 240 VAC

30 s

24 VAC/VDC

G9SA-321-T30

100 to 240 VAC

Two-hand controller

Main contacts

Auxiliary contact

Number of input channels

Rated voltage

Order code

3PST-NO

SPST-NC

2 channels

24 VAC/VDC

G9SA-TH301

100 to 240 VAC

Expansion unit

The expansion unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.

Main contacts

Auxiliary contact

Category

Order code

3PST-NO

SPST-NC

4

G9SA-EX301

Expansion units with OFF-delay outputs

The expansion unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.

Main contact form

Auxiliary contact

OFF-delay time

Order code

3PST-NO

SPST-NC

7.5 s

G9SA-EX031-T075

15 s

G9SA-EX031-T15

30 s

G9SA-EX031-T30

Specifications

Power input

Item

G9SA-301/TH301 / G9SA-501 / G9SA-321-T_

Power supply voltage

24 VAC/VDC: 24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC: 100 to 240 VAC, 50/60 Hz

Operating voltage range

85 to 110% of rated power supply voltage

Inputs

Item

G9SA-301/321-T_/TH301

G9SA-501

Input current

40 mA max.

60 mA max.

Contacts

Item

G9SA-301/501/321-T_/TH301/EX301/EX031-T_

Resistive load (cosφ= 1)

Rated load

250 VAC, 5 A

Rated carry current

5 A

Characteristics

Item

G9SA-301/TH301 / G9SA-501/321-T_ / G9SA-EX301/EX031-T_

Operating time

30 ms max. (not including bounce time)

Response time 1

10 ms max. (not including bounce time)

Durability

Mechanical

5,000,000 operations min. (at approx. 7,200 operations/hr)

Electrical

100,000 operations min. (at approx. 1,800 operations/hr)

Minimum permissible load
(reference value)

5 VDC, 1 mA

Ambient temperature

Operating: -25 to 55°C (with no icing or condensation)
Storage: -25 to 85°C (with no icing or condensation)


1. The response time is the time it takes for the main contact to open after the input is turned OFF.

1. The response time is the time it takes for the main contact to open after the input is turned OFF.

Avete delle domande?

Siamo a vostra intera disposizione.

Contattateci

Iscrivetevi agli aggiornamenti di prodotti

Newsletter sulle ultime novità e innovazioni in termini di prodotti, soluzioni e servizi direttamente nella vostra casella di posta.

Grazie per la tua iscrizione! Riceverai a breve una E-mail di conferma con un link per attivare il servizio. Questo sistema di iscrizione è stato scelto per ottemperare alla legge sulla privacy e garantisce la riservatezza del tuo indirizzo E-mail.

Purtroppo abbiamo problemi tecnici. Il tuo modulo non è stato ricevuto correttamente. Ci scusiamo per l'inconveniete e ti chiediamo per favore di riprovare più tardi.

Download

Documentazione di prodotto

Scarica le schede tecniche, i manuali e le brochure.

Vai al Download Center

Corsi di formazione

Accedete ai corsi di formazione offerti dai nostri tecnici qualificati. Dal livello principiante ad avanzato.

Visualizzate i corsi di formazione